English

English

Products

High Accuracy AC400V 1000kw Load Bank Outdoor Type For Generator/ UPS Testing

Type: container outdoor type Product name: AC400V- 800KW Resistive Load Bank Brand: Vilva (can OEM brand) Appication: Generator test/ UPS testing
inquiry now
details

1780569177703865.jpg

1MW~50MW Container Load Bank | Generator & Energy Storage Full Load Testing
Outdoor waterproof container load bank for power plant, energy storage & data center acceptance test. Custom high voltage solution available.

✅ Wide power range 1–50MW, customizable high voltage solution for generator, battery storage & grid acceptance witnessed test.
✅ All-in-one containerized unit, fast site deployment, saves your construction and shelter cost for outdoor commissioning.
✅ Built-in intelligent monitoring & multi-layer safety protection, prevent equipment damage during full-load continuous operation.

1.Core Features & Advantages
✅
IP rated outdoor container, rainproof & dustproof, direct on-site deployment without extra shelter.
✅One-click auto test, real-time data log, save your on-site labor cost.

✅Over-current / over-temperature protection, avoid equipment damage during full-load testing.
✅
Standard container size, easy sea/land transport, quick setup on site.
✅
Custom voltage (6kV/10kV etc.) available to match your generator & energy storage system.

                                            Click Here to Start Contacting Us


img-mv6g3yhx-aa97f47e(1).png
Q1: Can this container load bank perform full-step load simulation for generator & energy storage system acceptance test?

A1: Yes. It can simulate steady-state and step-changing resistive load to verify the performance of diesel generators, UPS systems and grid-connected energy storage equipment, to
complete factory and site acceptance without actual real user load.

Q2: What rated voltage systems are available? Does it support 415V Line / 230V Phase, 400V, 6.6kV, 11kV medium voltage options?

A2: Yes. Low voltage version supports 415V (230V phase) / 400V; Medium voltage models including 6.6kV, 11kV are available as customized options. 480V/277V is also optional.

Q3: Can multiple containerized load banks be paralleled together to achieve combined higher total load capacity for large power plant or big data center cluster testing?

A3: Yes. Multiple container units can be synchronized and paralleled. The control system can work together to realize combined large load for multi-generator parallel commissioning
and large-scale power system verification.

Q4: Can the system automatically generate editable acceptance test reports for EPC project handover?

A4: Yes. The system continuously records full test data, and can export editable acceptance test reports in PDF and CSV format for project delivery and client audit.

Q5: Do you provide overseas on-site commissioning, operator training and after-sales technical support? Is remote online commissioning available?

A5: Yes. We supply overseas on-site commissioning, operation training and long-term technical support. Remote online debugging is also available as an alternative solution.

Q6: What is the load adjustment step resolution?

A6: Standard load step resolution is 100kW. Finer adjustable load resolution can be customized as requested.

Q7: Does the equipment support remote monitoring & control via MODBUS TCP/IP or SCADA system connection?

A7: Yes. MODBUS-RTU and MODBUS TCP/IP communication are built-in. It supports remote load setting, real-time power/temperature data reading, and remote alarm monitoring, compatible with customer SCADA platform.

Q8: What is the cooling method of this container load bank? Forced air cooling or liquid cooling?

A8: Forced air cooling is standard configuration. Liquid cooling container version can be customized for high ambient temperature sites or high-density continuous load test requirements.

Q9: What is the maximum continuous running time under full rated load?

A9: It supports 24/7 continuous stable operation at rated full load.

Q10: Can it simulate programmable dynamic load profile, load step up/down, sudden load rejection for UPS switching test, generator transient response and grid fault simulation?

A10: Yes. It supports programmable dynamic load curves, step/ramp load changes and sudden load shedding. It can simulate power failure, UPS transfer switching and generator transient performance test.

Q11: What built-in safety protection functions are equipped? (over-temperature, over-current, over-voltage, under-voltage, emergency stop etc.)

A11: Built-in protections include over-temperature, over-current, over-voltage, under-voltage, fan failure protection, over-frequency /under-frequency protection and emergency stop. It will automatically cut off the load immediately once any alarm is triggered.

Q12: What is your production lead time for standard and customized container load bank models?

A12: Standard low voltage container models: 6–8 weeks. Custom medium voltage, liquid cooling or special design units: 10–16 weeks, final lead time depends on project specifications.

Q13: What electrical and thermal parameters can be recorded and stored during the load test?

A13: Recorded data includes three-phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency, cabinet temperature, running time and full alarm event logs.

Q14: Can the container design be customized? Such as container size, internal layout, cable access position, local control cabinet layout.

A14: Yes. Container dimension, cable inlet direction, control panel layout and external interface can be customized to match site installation requirements.



If you have any Load Bank tester needing, Please kindly contacting me!
Email: tompan@vilva-test.com
Whatsapp: +86 13066198582

Send a Message

If you have any questions or suggestions, please write down your questions or suggestions, we will answer your questions as soon as possible!

Submit
Hot Products
related products
Rack Mounted Liquid Cooled 5kW~10kW Resistive Load Bank
Rack Mounted Liquid Cooled 5kW~10kW Resistive Load Bank
Type: Portable type Rated Power: 12KW Rated Voltage: AC120V, Other voltage and frequency are available on demand Working Voltage: AC120V/50Hz Control mode: Loca...
50KW AC Resistive Load bank
50KW AC Resistive Load bank
Rated Power: 50KW Rated Voltage: AC220V, Other voltage and frequency are available on demand Working Voltage: AC220V/50Hz
AC 500kW~1000KW Resistive Load Bank for Generator UPS & Energy Storage Load Testing
AC 500kW~1000KW Resistive Load Bank for Generator UPS & Energy Storage Load Testing
Type: Cabinet type Product name: AC 500kW~1000KW Variable Resistive Load Bank Tester Brand: Vilva (can OEM brand) Appication: Generator test/ UPS testing etc. Con...
200KW AC Resistive Load bank
200KW AC Resistive Load bank
Rated Power: 200KW Rated Voltage: AC220V, Other voltage and frequency are available on demand Working Voltage: AC220V/50Hz
10KW AC Resistive Load bank
10KW AC Resistive Load bank
Rated Power: 10KW Rated Voltage: AC220V, Other voltage and frequency are available on demand Working Voltage: AC220V/50Hz
250KW AC Resistive Load bank
250KW AC Resistive Load bank
Rated Power: 250KW Rated Voltage: AC380V, Other voltage and frequency are available on demand Working Voltage: AC380V/50Hz
sign up for newsletter

wants to get latest updates! sign up for free.

submit
welcome !
submit

home

Products

News

contact